Spec
SDevice
伺服驅動器
 
								| Item | Specifications | |
|---|---|---|
| Performance | Speed Frequency Characteristics: 1.6kHz (load condition: load moment of inertia JL=Motor moment of inertia Jm) | |
| Tolrque control tolerance (repeatability): ±1% | ||
| MECHATROLINK Communications | Performance | Position control, speed control, and torque control through MECHATROLINK-Ⅲ communications | 
| Command Input | MECHATROLINK commands (for sequence, motion, data setting/reference, monitor, adjustment, and other commands.) | |
| Applicable servo motor capacity | 50W to 5kW | |
| Encoder resolution | 20-bit (incremental/absolute encoder), 13-bit (only for incremental encoder of SGMJV servomotors) | |
| Input Signals | Number of channels | 7ch. Signal alllocations and positive/negative logics can be modified. | 
| Function | Forward run prohibited, Reverse run prohibited, Forward torque limit, Reverse torque limit, Extaernal latch signal, Homing deceleration switch signal | |
| Output Signals | Number of channels | 3ch. Signal alllocations and positive/negative logics can be modified. | 
| Function | Positioning completion, Speed coincidence detection, Servomotor rotation detection, Servo ready, Torque limit detection, Speed limit detection, Break interlock, Warning, NEAR | |
| Protective Functions | Overcurrent, Overvoltage, Low voltage, Overload, Regeneratio error, Over speed, etc. | |
| Option Module Functions | Serial encoder communication input for fully-closed loop control | |
| Compliant Standards | UL*, CE marking (EMC directive, low voltage directive)*, Safety*, RoHS | |
| Safety Functions | EN954 category 3 Stop category 0, IEC61508 SIL 2 Input : Power module base block signal. Output : Safety circuit status monitor | |
*: Planning
| M-Ⅲ | |
|---|---|
| Profile | Standard servo | 
| Data size | 32byte, 48byte | 
| Transmission cycle | 0.125ms to 4ms |