Spec
Slave
變頻器驅動
Item | Specifications | |
---|---|---|
Rated Input/Output |
Max. Output Voltage | Depends on input voltage |
Max. Output Frequency | 400 Hz | |
Power Supply Characteristics |
Rated Voltage/ Rated Frequency |
Three-phase AC power supply 200 V Class: 200 to 240 Vac 50/60 Hz, 400 V Class: 380 to 480 Vac 50/60 Hz |
Allowable Voltage Fluctuation | −15% to+10% | |
Allowable Frequency Fluctuation | ±3% (Frequency fluctuation rate: 1 Hz/100 ms or less) | |
Allowable Power Voltage Imbalance between Phases | less than 2% | |
Control Characteristics |
Control Method | Sine-wave PWM [V/f control, V/f Control with PG, Open Loop vector control, Closed Loop Vector Control, Open Loop Vector Control for PM, Advanced Open Loop Vector Control for PM, Closed Loop Vector Control for PM (switched by parameter setting)] |
Harmonic Current Distortion Rate | 5% or less (IEEE 519) | |
Input Power Factor | 0.98 or more (for rated load) | |
Overload Tolerance | HD Rating: 150% of rated output current for 60 s, ND Rating: 120% of rated output current for 60 s (Derating may be required for repetitive loads) | |
Status Output | 1 C-relay output at failures, 1 a contact output (multi-function) during operation, 2 multi-function PHC outputs selectable at alarms, 2 multi-function analog outputs selectable for analog outputs, Pulse train output: 1 (multi-function) |
M-Ⅰ | M-Ⅱ | ||||
---|---|---|---|---|---|
17-byte | 17-byte | 32-byte | |||
Command | Inverter | × | × | × | |
Transmission cycle | =Comm. Cycle | 2ms | 500μs to 8ms | 1ms to 8ms | |
≠Comm. Cycle | 2ms to 8ms |
M-Ⅲ | |
---|---|
Profile | Standard Inverter |
Data size | 32byte, 48byte |
Transmission cycle | 0.250ms to 8ms |
YASKAWA ELECTRIC CORPORATION